pitot tubes, hot wires or Laser Doppler Velocimetry. Flow uniformity can be estimated using velocity sensing devices, i.e. The flow across the area covered by the anemometer shall be uniform. The presence of the anemometer shall not substantially affect the flow field in the wind tunnel. There are also special requirements for the wind tunnel.
#Anemometer calibration iso#

The side hole measures the static pressure. The front hole is placed directly into the fluid flow and it measures the stagnation pressure. The pilot tube is a slim tube which has two holes on it. Pitot tubes: They are pressure measuring instruments used to measure fluid flow velocity.The instrument under test is placed in the middle of the tunnel and it is fastened so it does not move. The fan must have straightening vanes to smooth the airflow. They have a fan which moves the air inside. A wind tunnel: Wind tunnels are large tubes with air moving inside.The equipment used for the calibration is:

Although the calibration procedure refers to cup anemometers, it is widely accepted for the calibration of any type of anemometer.
#Anemometer calibration professional#
Products tested includes anemometers manufactured by:Ībbirko, Airflow, Airflow Developments, Airflow Instruments, Alnor, Alphatek, AMECal, Amprobe, ATP, CEM, Chauvin Arnoux, Dantec, Deuta, Digitron, DP Measurments, Dwyer, ETI, Eurisem, Extech, Fluke, Greisinger, Instrotech, JDC, Kaindl, Kane & May, Kanomax, Kestrel, Kimo, Lowne Instruments, Lutron, Mannix, Martindale, Mastech, Mastercool, Meitav, Metrel, Munro, Omega, PCE Instruments, Professional Instruments, Prova, Rototherm, SKD, Smart Sensor, Speedtech, Tecpel, Tenma, Testo, TFA, TSI and WM Instruments.Anemometers are calibrated in accordance to Annex F of IEC 6 “Wind turbines – Part 12-1: Power performance measurements of electricity producing wind turbines”.

*Specific model calibration points dependent upon calibration capabilities and instrument ranges. Typical standard calibration points of Pitot tubes 3, 5, 10, 15 & 25* m/s Typical standard calibration points of thermal anemometers 0.3, 1, 2, 5, 10 & 25* m/s Typical standard calibration points of vane anemometers 0.5, 1, 2, 5, 10 & 25* m/s Custom calibrations available, dependent upon calibration capabilities and instrument ranges. Unless requested by the client at the time of calibration vane anemometers are calibrated at xxxxĪll calibrations are conducted at standard calibration points, or as previous, unless instructed overwise. The laboratory is equipped with all the latest technologies in the field of air velocity measurement including a laser Doppler anemometer, which gives the facility the capability of offering excellent levels of Calibration and Measurement Capability (CMC) Expressed as an Expanded Uncertainty.Ĭalibration options include traceable to national standards under the Instrument Solutions ISO 9001 accreditation or UKAS accredited calibrations against the ISO 17025 standard. BSRIA Instrument Solutions air velocity laboratory is able to offer calibrations on a wide range of instruments at ambient (laboratory) temperatures including vane anemometers up to 120 mm in diameter, thermal anemometers, cup anemometers, pitot tubes and velometers.